Check out the IROC at AAPM!
|
Time |
Location |
Talk Title |
|
Monday, July 30, 2012 |
Ballroom B |
The Radiological Physics Center's Quality Audit Program: Where Can We Improve?, David Followill |
|
Monday, July 30, 2012 |
Ballroom B |
Comparison of Proton Therapy Institutional Data Collected by the IROC, Paige Summers |
|
Monday, July 30, 2012 |
Ballroom B |
The Approval Process for the Use of Proton Therapy in NCI-Sponsored Clinical Trials, Paige Summers |
|
Monday, July 30, 2012 |
Ballroom B |
An Analysis of 13,000 Patient-Specific IMRT QA Results From 13 Different Clinical Treatment Services, Kiley Pulliam |
|
Tuesday, July 31, 2012 |
Room 217BCD |
Investigation of a Commercial OSLD System for CT Dosimetry, Sarah Scarboro |
|
Wednesday, August 01, 2012 |
Room 213AB |
Second Cancers From Radiation Therapy Procedures, Stephen Kry, Rebecca Howell |
|
Thursday, August 02, 2012 |
Ballroom B |
Credentialing Results From a Spine Anthropomorphic Phantom, Andrea Molineu |
|
Thursday, August 02, 2012 |
Ballroom B |
The Magnitude of H&N IMRT Dose Delivery Errors From Three Possible Failure Modes: Beam Quality, Symmetry, and MLC Position, Jacqueline Tonigan |
2D Vs 3D Gamma Analysis: Establishment of Comparable Clinical Action Limits
SU-E-T-41 K Pulliam*, R Bosca, D , J O'Daniel, Followill, S Kry
The Effects of Image Resolution and Noise On the Gamma Dose Distribution Comparison Method for IMRT QA
SU-E-T-43 J Huang*, K Pulliam, D Followill, S Kry
Development and Implementation of a Remote Audit Tool for High Dose Rate (HDR) Ir-192 Brachytherapy Using Optically Stimulated Luminescence Dosimetry
SU-E-T-81 K Casey*, P Alvarez, A Lawyer, S Kry, R Howell, S Davidson, D Followill
Development and Implementation of the Use of Optically Stimulated Luminescent Detectors in the Radiological Physics Center Anthropomorphic Quality Assurance Phantoms
SU-E-T-86 J Bergene*, S Kry, A Molineu, D Bellezza, L Court, P Alvarez, V Johnson, D Followill
Investigation of 3D Dosimetry for An Anthropomorphic Spine Phantom
SU-E-T-95 R Grant*, G Ibbott, J Yang, J Adamovics, D Followill
Evaluation of the Characteristics of TLD LiF:Mg.Ti-100 Powder: A Measure of Consistency Between Multiple Batches of Powder
SU-E-T-102 P Alvarez*, J Aguirre, S Smith, D Followill
Three-Dimensional Measurements of Dose and LET From a Proton Beam Via Polymer Gel Dosimetry
SU-E-T-103 K Vredevoogd*, G Ibbott, M Gillin, N Sahoo, S Kry, K Gifford, M Maryanski
The Radiological Physics Center's Anthropomorphic Quality Assurance Phantom Program
SU-E-T-180 C Amador*, N Hernandez, A Molineu, P Alvarez, D Followill
Design, Development, and Evaluation of a Modified, Anthropomorphic, Head, Quality Assurance Phantom for Use in Stereotactic Radiosurgery
SU-E-T-190 A Faught*, S Kry, D Luo, A Molineu, D Bellezza, R Gerber, S Davidson, W Bosch, J Galvin, R Drzymala, R Timmerman, J Sheehan, M Gillin, G Ibbott, D Followill
The Radiological Physics Center's Credentialing Dosimetry Reviews: Their Effect On Clinical Trial Deviation Rates
SU-E-T-199 A Hollan*, J Lowenstein, H Nguyen, F Hall, J Roll, I Harris, D Followill
High-Energy Photon Standard Dosimetry Data: A Quality Assurance Tool
SU-E-T-223 J Lowenstein*, S Kry, A Molineu, P Alvarez, J Aguirre, P Summers, D Followill
Dosimetry of Double Scattered Proton Beam Fields Used for Cranio-Spinal Irradiation
SU-E-T-291 X Song*, N Sahoo, R Wu, M Taylor, R Georges, X Zhu, P Summers, M Gillin
Ion Recombination Correction Factors (Pion) for Varian TrueBeam High Dose Rate Therapy Beams
SU-E-T-375 S Kry*, R Popple, A Molineu, D Followill
Evaluation of the Anisotropic Analytical Algorithm (AAA) Heterogeneity Correction Dose Calculation in Flattened and Flattening-Filter-Free (FFF) Beams for High Energy X-Ray Beams Using the Radiological Physics Center (IROC) Lung Phantom
SU-E-T-447 R Repchak, A Molineu, R Popple, S Kry, R Howell, D Followill
Calculation of High Resolution and Material-Specific Photon Energy Deposition Kernels
SU-E-T-510 J Huang*, N Childress, S Kry
Experimental Evaluation of Deterministic Acuros XB Radiation Transport Algorithm for Heterogeneity Dose Calculation Using the Radiological Physics Center's Lung Phantom
SU-E-T-519 T Han*, F Mourtada, R Repchak, J Tonigan, J Mikell, R Howell, M Salehpour, A Molineu, D Followill
Evaluation of Zebra Multi-Layer Ionization Chamber System for Patient Treatment Field and Machine QA for Spot Scanning and Passive Scattering Proton Beams
SU-D-BRCD-1 S Dhanesar*, N Sahoo, M Taylor, X Song, F Poenisch, P Sum